OBC-P0D2017
VOLVO
OBC-P0D2017 - Battery Charger Output Voltage Performance. General Electrical Failures. Circuit voltage above threshold
Układ
Ładowarka pokładowa (OBC)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
1 modelV60 (2011–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
The battery charger control module (OBC) checks the output voltage once charging has started through the charging cable. The code is set when the voltage is too high, and the fault may lie in a defective charging cable or in the battery charger itself.
Możliwe przyczyny
- The charging cable is defective
- Internal fault in the battery charger control module (OBC)
Co możesz zrobić
- 1Look at the charging cable for breaks, damage and chafing
- 2If you have another compatible charging cable, try it and see whether the fault remains
- 3If the cable is intact and the fault remains, have a workshop check the battery charger
- 4Do not work on the battery charger or its connections yourself; it is part of the high-voltage section and a job for a workshop
Objawy, które możesz zauważyć2
- Charging of the high voltage battery from an external cable does not work
- The lamp in the charging socket signals a fault or reduced charging
Na co może wpływać usterka1
- No charging of the high voltage battery can take place
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.