LPG-0215 - Fuel shut-off valve. Faulty signal
System
Liquid Petroleum Gas (LPG)
Volvo models this fault code applies to
Applies to the following models:
2 modelsS40 (1996–2004), V40 (1996–2004)
Show models by year and engine (2)
What does this fault code mean?
The fuel shut-off valve cuts off the gas flow when it is operated. The LPG control module sets the code when the valve is activated and the fuel mixture has been too rich for a longer time while the engine runs on gas.
Possible causes
- Defective fuel shut-off valve
What you can do
- 1Check the fuse for the circuit to the fuel shut-off valve and that the system relay works
- 2Have a workshop run the test with the engine idling on gas and the connector disconnected from the shut-off valve; the engine should then stop
- 3Have a workshop check the fuel shut-off valve and replace it if it is defective
- 4Erase the code and road test the car on gas to see whether it returns
Symptoms you may notice1
- Deterioration in performance
General guidance for car owners. Diagnosis on the car can point to a different cause.