| Kod | Znaczenie |
|---|---|
| CPM-B1D2211 | Coolant Temperature Sensor. General Electrical Failures. Circuit short to ground2015 |
| CPM-B1D2215 | Coolant Temperature Sensor. General Electrical Failures. Circuit short to battery or open2015 |
| CPM-B1D2313 | Overheat Sensor. General Electrical Failures. Circuit open2015 |
| CPM-B1D2411 | Glow Plug. General Electrical Failures. Circuit short to ground2015 |
| CPM-B1D2415 | Glow Plug. General Electrical Failures. Circuit short to battery or open2015 |
| CPM-B1D2511 | Heater Fuel Pump. General Electrical Failures. Circuit short to ground2015 |
| CPM-B1D2515 | Heater Fuel Pump. General Electrical Failures. Circuit short to battery or open2015 |
| CPM-B1D2611 | Combustion Air Blower. General Electrical Failures. Circuit short to ground2015 |
| CPM-B1D2615 | Combustion Air Blower. General Electrical Failures. Circuit short to battery or open2015 |
| CPM-B1D2692 | Combustion Air Blower. Component Failures. Performance or incorrect operation2015 |
| CPM-B1D2693 | Combustion Air Blower. Component Failures. No operation2015 |
| CPM-B1D2711 | Heater Coolant Pump. General Electrical Failures. Circuit short to ground2015 |
| CPM-B1D2715 | Heater Coolant Pump. General Electrical Failures. Circuit short to battery or open2015 |
| CPM-B1D2811 | Fuel pre-heater. General Electrical Failures. Circuit short to ground2015 |
| CPM-B1D2815 | Fuel pre-heater. General Electrical Failures. Circuit short to battery or open2015 |
| CPM-B1D2993 | No start, even after restart attempt. Component Failures. No operation2015 |
| CPM-B1D3194 | Flame detected prior to normal operation. Component Failures. Unexpected operation2015 |
| CPM-B1D3292 | Multiple flame interruption during heating cycle. Component Failures. Performance or incorrect operation2015 |
| CPM-B1D3392 | Flame interruption during normal operation. Component Failures. Performance or incorrect operation2015 |
| CPM-B1D3468 | Heater in lock out mode. Algorithm Based Failures. Event information2015 |
| CPM-U001000 | Medium Speed CAN Communication Bus. General Failure Information. No sub type information2015 |
| CPM-U002808 | Vehicle Communication Bus A. General Failure Information. Bus Signal / Message Failures2015 |
| CPM-U030000 | Internal Control Module Software Incompatibility. General Failure Information. No sub type information2015 |
| CPM-U1A3787 | Crash Status Telegram. Bus Signal / Message Failures. Missing message2015 |
| CPM-U210100 | Control Module Configuration Incompatible. General Failure Information. No sub type information2015 |
| CPM-U300016 | Control Module. General Electrical Failures. Circuit voltage below threshold2015 |
| CPM-U300017 | Control Module. General Electrical Failures. Circuit voltage above threshold2015 |
| CPM-U300043 | Control Module. System Internal Failures. Special memory failure2015 |
| CPM-U300049 | Control Module. System Internal Failures. Internal electronic failure2015 |
| CPM-U300362 | Battery Voltage. Algorithm Based Failures. Signal compare failure2015 |