POT-B111D11
VOLVO
POT-B111D11 - Boot/Trunk motor open. General Electrical Failures. Circuit short to ground
Układ
Sterownik elektrycznej klapy bagażnika (POT)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
2 modeleV70 (2008–), XC70 (2008–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
The tailgate control module (POT) checks the voltage across the motor used to unlock the tailgate. The fault is stored when the DC voltage is too low, which can be due to the wire to the unlock motor being short-circuited to ground, or the motor itself being damaged.
Możliwe przyczyny
- The wire to the unlock motor is short-circuited to ground
- The unlock motor is damaged
Co możesz zrobić
- 1Check the fuse for the tailgate control module in the fuse box. Its location is shown in the owner's manual or on the cover of the box
- 2Look for chafed wires to the unlock motor, especially where the cable enters the tailgate
- 3Use a multimeter to check that the wire to the unlock motor has no contact with ground (the body)
- 4If the wire is intact but the fault remains, a workshop should replace the unlock motor
Objawy, które możesz zauważyć3
- The tailgate is hard to open
- The tailgate is hard to close
- Automatic opening and closing of the tailgate does not work
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.