| Kod | Znaczenie |
|---|---|
| POT-B108467 | Boot/Trunk Motor Close switch. Algorithm Based Failures. Signal incorrect after event2008–2015 |
| POT-B10D067 | Trunk Latch clutch switch. Algorithm Based Failures. Signal incorrect after event2008–2011 |
| POT-B111D11 | Boot/Trunk motor open. General Electrical Failures. Circuit short to ground2008–2011 |
| POT-B111D13 | Boot/Trunk motor open. General Electrical Failures. Circuit open2008–2011 |
| POT-B111F11 | Boot/Trunk motor close. General Electrical Failures. Circuit short to ground2008–2015 |
| POT-B111F12 | Boot/Trunk motor close. General Electrical Failures. Circuit short to battery2011–2015 |
| POT-B111F13 | Boot/Trunk motor close. General Electrical Failures. Circuit open2008–2015 |
| POT-B113E23 | External Boot/Trunk release switch. General Signal Failures. Signal stuck low2008–2015 |
| POT-B116112 | Left rear anti-pinch sensor. General Electrical Failures. Circuit short to battery2008–2010 |
| POT-B116113 | Left rear anti-pinch sensor. General Electrical Failures. Circuit open2008–2010 |
| POT-B116123 | Left rear anti-pinch sensor. General Signal Failures. Signal stuck low2008–2010 |
| POT-B116212 | Right rear anti-pinch sensor. General Electrical Failures. Circuit short to battery2008–2010 |
| POT-B116213 | Right rear anti-pinch sensor. General Electrical Failures. Circuit open2008–2010 |
| POT-B116223 | Right rear anti-pinch sensor. General Signal Failures. Signal stuck low2008–2010 |
| POT-B117867 | Boot/Trunk ajar switch. Algorithm Based Failures. Signal incorrect after event2008–2011 |
| POT-B118711 | Trunk motor. General Electrical Failures. Circuit short to ground2011–2015 |
| POT-B118712 | Trunk motor. General Electrical Failures. Circuit short to battery2008–2015 |
| POT-B118713 | Trunk motor. General Electrical Failures. Circuit open2011–2015 |
| POT-B11C423 | Boot/trunk close button. General Signal Failures. Signal stuck low2008–2015 |
| POT-B1A9904 | Power on reset. General Failure Information. System Internal Failures2008–2015 |
| POT-C101767 | Boot/Trunk Primary Switch. Algorithm Based Failures. Signal incorrect after event2011–2015 |
| POT-C102267 | Boot/Trunk Secondary Switch. Algorithm Based Failures. Signal incorrect after event2011–2015 |
| POT-C112712 | Position Sensor. General Electrical Failures. Circuit short to battery2011–2015 |
| POT-C112767 | Position Sensor. Algorithm Based Failures. Signal incorrect after event2011–2015 |
| POT-C1A4396 | Motor supply circuit. Component Failures. Component internal failure2008–2015 |
| POT-P060400 | Internal Control Module Random Access Memory (RAM) Error. General Failure Information. No sub type information2008–2015 |
| POT-P060500 | Internal Control Module Read Only Memory (ROM) Error. General Failure Information. No sub type information2008–2015 |
| POT-P093212 | Hydraulic Pressure Sensor Circuit. General Electrical Failures. Circuit short to battery2008–2011 |
| POT-P093214 | Hydraulic Pressure Sensor Circuit. General Electrical Failures. Circuit short to ground or open2008–2011 |
| POT-P093267 | Hydraulic Pressure Sensor Circuit. Algorithm Based Failures. Signal incorrect after event2008–2011 |
| POT-P094513 | Hydraulic Pump Relay Circuit / Open. General Electrical Failures. Circuit open2008–2011 |
| POT-P094711 | Hydraulic Pump Relay Circuit Low. General Electrical Failures. Circuit short to ground2008–2011 |
| POT-P094812 | Hydraulic Pump Relay Circuit High. General Electrical Failures. Circuit short to battery2008–2011 |
| POT-P124011 | Sensor Power Supply. General Electrical Failures. Circuit short to ground2011–2015 |
| POT-P124012 | Sensor Power Supply. General Electrical Failures. Circuit short to battery2011–2015 |
| POT-P160342 | EEPROM Malfunction. System Internal Failures. General memory failure2008–2015 |
| POT-U001000 | Medium Speed CAN Communication Bus. General Failure Information. No sub type information2008–2015 |
| POT-U014000 | Lost Communication With Central electronic module. General Failure Information. No sub type information2008–2015 |
| POT-U030000 | Internal Control Module Software Incompatibility. General Failure Information. No sub type information2008–2015 |
| POT-U042268 | Invalid Data Received From Central electronic module. Algorithm Based Failures. Event information2008–2015 |
| POT-U201409 | Control Module Hardware. General Failure Information. Component Failures2011–2015 |
| POT-U201A54 | Control Module Main Calibration Data. System Programming Failures. Missing calibration2008–2015 |
| POT-U210000 | Control Module Not Configured. General Failure Information. No sub type information2008–2015 |
| POT-U210100 | Control Module Configuration Incompatible. General Failure Information. No sub type information2008–2015 |
| POT-U300316 | Battery Voltage. General Electrical Failures. Circuit voltage below threshold2008–2015 |
| POT-U300317 | Battery Voltage. General Electrical Failures. Circuit voltage above threshold2008–2015 |
| POT-U300362 | Battery Voltage. Algorithm Based Failures. Signal compare failure2008–2015 |