Power Operated Tailgate (POT)
Volvo V70 (2008–) – Power Operated Tailgate (POT) fault codes
47 fault codes
The same fault code can mean different things depending on model year and engine. Each meaning is therefore shown on its own row, with exactly which cars it applies to.
| Code | Meaning |
|---|---|
| POT-B108467 | Boot/Trunk Motor Close switch. Algorithm Based Failures. Signal incorrect after event2008–2015 |
| POT-B10D067 | Trunk Latch clutch switch. Algorithm Based Failures. Signal incorrect after event2008–2011 |
| POT-B111D11 | Boot/Trunk motor open. General Electrical Failures. Circuit short to ground2008–2011 |
| POT-B111D13 | Boot/Trunk motor open. General Electrical Failures. Circuit open2008–2011 |
| POT-B111F11 | Boot/Trunk motor close. General Electrical Failures. Circuit short to ground2008–2015 |
| POT-B111F12 | Boot/Trunk motor close. General Electrical Failures. Circuit short to battery2011–2015 |
| POT-B111F13 | Boot/Trunk motor close. General Electrical Failures. Circuit open2008–2015 |
| POT-B113E23 | External Boot/Trunk release switch. General Signal Failures. Signal stuck low2008–2015 |
| POT-B116112 | Left rear anti-pinch sensor. General Electrical Failures. Circuit short to battery2008–2010 |
| POT-B116113 | Left rear anti-pinch sensor. General Electrical Failures. Circuit open2008–2010 |
| POT-B116123 | Left rear anti-pinch sensor. General Signal Failures. Signal stuck low2008–2010 |
| POT-B116212 | Right rear anti-pinch sensor. General Electrical Failures. Circuit short to battery2008–2010 |
| POT-B116213 | Right rear anti-pinch sensor. General Electrical Failures. Circuit open2008–2010 |
| POT-B116223 | Right rear anti-pinch sensor. General Signal Failures. Signal stuck low2008–2010 |
| POT-B117867 | Boot/Trunk ajar switch. Algorithm Based Failures. Signal incorrect after event2008–2011 |
| POT-B118711 | Trunk motor. General Electrical Failures. Circuit short to ground2011–2015 |
| POT-B118712 | Trunk motor. General Electrical Failures. Circuit short to battery2008–2015 |
| POT-B118713 | Trunk motor. General Electrical Failures. Circuit open2011–2015 |
| POT-B11C423 | Boot/trunk close button. General Signal Failures. Signal stuck low2008–2015 |
| POT-B1A9904 | Power on reset. General Failure Information. System Internal Failures2008–2015 |
| POT-C101767 | Boot/Trunk Primary Switch. Algorithm Based Failures. Signal incorrect after event2011–2015 |
| POT-C102267 | Boot/Trunk Secondary Switch. Algorithm Based Failures. Signal incorrect after event2011–2015 |
| POT-C112712 | Position Sensor. General Electrical Failures. Circuit short to battery2011–2015 |
| POT-C112767 | Position Sensor. Algorithm Based Failures. Signal incorrect after event2011–2015 |
| POT-C1A4396 | Motor supply circuit. Component Failures. Component internal failure2008–2015 |
| POT-P060400 | Internal Control Module Random Access Memory (RAM) Error. General Failure Information. No sub type information2008–2015 |
| POT-P060500 | Internal Control Module Read Only Memory (ROM) Error. General Failure Information. No sub type information2008–2015 |
| POT-P093212 | Hydraulic Pressure Sensor Circuit. General Electrical Failures. Circuit short to battery2008–2011 |
| POT-P093214 | Hydraulic Pressure Sensor Circuit. General Electrical Failures. Circuit short to ground or open2008–2011 |
| POT-P093267 | Hydraulic Pressure Sensor Circuit. Algorithm Based Failures. Signal incorrect after event2008–2011 |
| POT-P094513 | Hydraulic Pump Relay Circuit / Open. General Electrical Failures. Circuit open2008–2011 |
| POT-P094711 | Hydraulic Pump Relay Circuit Low. General Electrical Failures. Circuit short to ground2008–2011 |
| POT-P094812 | Hydraulic Pump Relay Circuit High. General Electrical Failures. Circuit short to battery2008–2011 |
| POT-P124011 | Sensor Power Supply. General Electrical Failures. Circuit short to ground2011–2015 |
| POT-P124012 | Sensor Power Supply. General Electrical Failures. Circuit short to battery2011–2015 |
| POT-P160342 | EEPROM Malfunction. System Internal Failures. General memory failure2008–2015 |
| POT-U001000 | Medium Speed CAN Communication Bus. General Failure Information. No sub type information2008–2015 |
| POT-U014000 | Lost Communication With Central electronic module. General Failure Information. No sub type information2008–2015 |
| POT-U030000 | Internal Control Module Software Incompatibility. General Failure Information. No sub type information2008–2015 |
| POT-U042268 | Invalid Data Received From Central electronic module. Algorithm Based Failures. Event information2008–2015 |
| POT-U201409 | Control Module Hardware. General Failure Information. Component Failures2011–2015 |
| POT-U201A54 | Control Module Main Calibration Data. System Programming Failures. Missing calibration2008–2015 |
| POT-U210000 | Control Module Not Configured. General Failure Information. No sub type information2008–2015 |
| POT-U210100 | Control Module Configuration Incompatible. General Failure Information. No sub type information2008–2015 |
| POT-U300316 | Battery Voltage. General Electrical Failures. Circuit voltage below threshold2008–2015 |
| POT-U300317 | Battery Voltage. General Electrical Failures. Circuit voltage above threshold2008–2015 |
| POT-U300362 | Battery Voltage. Algorithm Based Failures. Signal compare failure2008–2015 |