CodeMeaning
POT-B108467Boot/Trunk Motor Close switch. Algorithm Based Failures. Signal incorrect after event2008–2015
POT-B10D067Trunk Latch clutch switch. Algorithm Based Failures. Signal incorrect after event2008–2011
POT-B111D11Boot/Trunk motor open. General Electrical Failures. Circuit short to ground2008–2011
POT-B111D13Boot/Trunk motor open. General Electrical Failures. Circuit open2008–2011
POT-B111F11Boot/Trunk motor close. General Electrical Failures. Circuit short to ground2008–2015
POT-B111F12Boot/Trunk motor close. General Electrical Failures. Circuit short to battery2011–2015
POT-B111F13Boot/Trunk motor close. General Electrical Failures. Circuit open2008–2015
POT-B113E23External Boot/Trunk release switch. General Signal Failures. Signal stuck low2008–2015
POT-B116112Left rear anti-pinch sensor. General Electrical Failures. Circuit short to battery2008–2010
POT-B116113Left rear anti-pinch sensor. General Electrical Failures. Circuit open2008–2010
POT-B116123Left rear anti-pinch sensor. General Signal Failures. Signal stuck low2008–2010
POT-B116212Right rear anti-pinch sensor. General Electrical Failures. Circuit short to battery2008–2010
POT-B116213Right rear anti-pinch sensor. General Electrical Failures. Circuit open2008–2010
POT-B116223Right rear anti-pinch sensor. General Signal Failures. Signal stuck low2008–2010
POT-B117867Boot/Trunk ajar switch. Algorithm Based Failures. Signal incorrect after event2008–2011
POT-B118711Trunk motor. General Electrical Failures. Circuit short to ground2011–2015
POT-B118712Trunk motor. General Electrical Failures. Circuit short to battery2008–2015
POT-B118713Trunk motor. General Electrical Failures. Circuit open2011–2015
POT-B11C423Boot/trunk close button. General Signal Failures. Signal stuck low2008–2015
POT-B1A9904Power on reset. General Failure Information. System Internal Failures2008–2015
POT-C101767Boot/Trunk Primary Switch. Algorithm Based Failures. Signal incorrect after event2011–2015
POT-C102267Boot/Trunk Secondary Switch. Algorithm Based Failures. Signal incorrect after event2011–2015
POT-C112712Position Sensor. General Electrical Failures. Circuit short to battery2011–2015
POT-C112767Position Sensor. Algorithm Based Failures. Signal incorrect after event2011–2015
POT-C1A4396Motor supply circuit. Component Failures. Component internal failure2008–2015
POT-P060400Internal Control Module Random Access Memory (RAM) Error. General Failure Information. No sub type information2008–2015
POT-P060500Internal Control Module Read Only Memory (ROM) Error. General Failure Information. No sub type information2008–2015
POT-P093212Hydraulic Pressure Sensor Circuit. General Electrical Failures. Circuit short to battery2008–2011
POT-P093214Hydraulic Pressure Sensor Circuit. General Electrical Failures. Circuit short to ground or open2008–2011
POT-P093267Hydraulic Pressure Sensor Circuit. Algorithm Based Failures. Signal incorrect after event2008–2011
POT-P094513Hydraulic Pump Relay Circuit / Open. General Electrical Failures. Circuit open2008–2011
POT-P094711Hydraulic Pump Relay Circuit Low. General Electrical Failures. Circuit short to ground2008–2011
POT-P094812Hydraulic Pump Relay Circuit High. General Electrical Failures. Circuit short to battery2008–2011
POT-P124011Sensor Power Supply. General Electrical Failures. Circuit short to ground2011–2015
POT-P124012Sensor Power Supply. General Electrical Failures. Circuit short to battery2011–2015
POT-P160342EEPROM Malfunction. System Internal Failures. General memory failure2008–2015
POT-U001000Medium Speed CAN Communication Bus. General Failure Information. No sub type information2008–2015
POT-U014000Lost Communication With Central electronic module. General Failure Information. No sub type information2008–2015
POT-U030000Internal Control Module Software Incompatibility. General Failure Information. No sub type information2008–2015
POT-U042268Invalid Data Received From Central electronic module. Algorithm Based Failures. Event information2008–2015
POT-U201409Control Module Hardware. General Failure Information. Component Failures2011–2015
POT-U201A54Control Module Main Calibration Data. System Programming Failures. Missing calibration2008–2015
POT-U210000Control Module Not Configured. General Failure Information. No sub type information2008–2015
POT-U210100Control Module Configuration Incompatible. General Failure Information. No sub type information2008–2015
POT-U300316Battery Voltage. General Electrical Failures. Circuit voltage below threshold2008–2015
POT-U300317Battery Voltage. General Electrical Failures. Circuit voltage above threshold2008–2015
POT-U300362Battery Voltage. Algorithm Based Failures. Signal compare failure2008–2015